Tawk.to

PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

About Us

Tampilkan postingan dengan label hach turbidity meter. Tampilkan semua postingan

HACH TL23 Series Benchtop Laboratory Turbidimeter

 


HACH TL23 Series Benchtop Laboratory Turbidimeter

  


HACH TL23 Series Benchtop Laboratory Turbidimeter

The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications.
Hach's new TL23 lab turbidimeter brings a new face to the trusted legacy 2100N and 2100AN turbidimeters. It utilizes the same optic bloc while delivering an improved user experience with its intuitive interface, which ties perfectly to the rest of Hach's laboratory instruments. 
Having the same optic bloc means that you can replace your old 2100N/AN with a TL23 turbidity meter without having tochange any of your standard operating procedures.

Improved and intuitive design
A smart device for more reliable measurements
Easy to use. Easy to Be Right

HACH TL23 Series Benchtop Laboratory Turbidimeter

HACH TL23 Series Benchtop Laboratory Turbidimeter
AccuracyRatio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU,
±5% of reading from 1000 - 4000 NTU based on formazin primary standard Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Air PurgeDry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
CertificationsCE, KC, RCM
CommunicationUSB
Data
Logging
2000 total logs, includes reading log,
verification log and calibration log
Dimensions
(H x W x D)
153 mm x 395 mm x 305 mm
Display17.8 mm (7 in.) color touch screen
Interface2 USB-A ports for USB flash drive, external printer,keyboard and barcode scanner
Light SourceTungsten filament lamp
Measurement
Method
Nephelometric
ModelTL2300 EPA
Operating
Temperature 
Range
0 - 40 °C
Power
Requirements
(Amps)
3.4 A
Power
Requirements
(Hz)
50/60 Hz
Power
Requirements
(Voltage)
100 - 240 VAC
RangeNTU (Ratio on): 0 - 4000 ; NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 980 ; EBC (Ratio off): 0 - 9.8
Reading
Modes
Single, continuous, Rapidly Settling Turbidity™,
signal averaging on or off, ratio on or off
RegulatoryMeets EPA Method 180.1
Repeatability±1% of reading or 0.01 NTU,
whichever is greater (under reference conditions)
Response TimeSignal averaging off: 6.8 seconds / Signal averaging on: 14 seconds
(when 10 measurements are used to calculate the average)
Sample Cell
Compatibility
Round cells 95 x 25 mm (3.74 x 1 in.)
borosilicate glass with rubber-lined screw caps
Note: Smaller sample cells(less than 25 mm)
can be used when a cell adapter is used.
Sample
Requirements
25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
Stabilization TimeRatio on: 30 minutes after start-up
Ratio off: 60 minutes after start-up
Storage Conditions-20 to 60 °C
UnitsNTU and EBC
Weight3.0 kg


PT . Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan general laboratory dan instrument equipment,  seperti  HACH TL23 Series Benchtop Laboratory Turbidimeter , kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : Thermo Fisher Scientific, Hach, Hanna Instrument, YSI dan lain - lain ; Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

HACH TL23 Series Benchtop Laboratory Turbidimeter
  • PT. Mora Anugerah Berkat (M.A.B)
  • Click Here : TL23 Series Laboratory Turbidimeters Brochure
  • Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,
  • Kota Tangerang - Provinsi Banten
  • Phone : 021 7345.7064
  • Mobile : 0812.8140.0749 / 0812.8770.5470 
  • Chat : Whats App, Line, WeChat, Telegram
  • Website :  www.moraanugerah.id  -  www.moraanugerah.com
  • Email : marketing@moraanugerah.com - marketing_div@moraanugerah.com - info@moraanugerah.com


Hach 2100Q and 2100Qis Portable Turbidimeters



Hach 2100Q and 2100Qis Portable Turbidimeters

Easiest calibration and verification with accurate results every time.

The Hach 2100Q and 2100Qis Portable Turbidimeters offer unsurpassed ease of use and accuracy in turbidity measurement. Only Hach offers this combination of advanced features including assisted calibration, simplified data transfer, and innovative measurement techniques that give you accurate results every time.

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Easy On-Screen Assisted Calibration and Verification


The 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal™ calibration offer a simplified solution for low level measurements.

Convenient Data Logging


Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.

Simple Data Transfer



Customizable power and connectivity modules provide smooth data transfer and flexibility. Optional USB+Power Module allows data download to any computer via USB port, providing superior data integrity and availability.


Optical System for Precision in the Field


The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, allowing you to achieve laboratory-grade performance on a wide range of samples, even under di@cult site conditions.


Accuracy for Rapidly Settling Samples


The innovative Rapidly Settling Turbidity™ mode provides accurate, repeatable measurements for di@cult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Two Models forpecific USEPA Requirements


The 2100Q Turbidimeter is compliant with USEPA Method 180.1 design criteria. The 2100Qis Turbidimeter is compliant with ISO 7027 design criteria.


Hach 2100Q and 2100Qis Portable Turbidimeters

Hach 2100Q and 2100Qis Portable Turbidimeters
Specification
Measurement
Method
Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) to the transmitted light scatter signal.Operating
Conditions
Temperature : 0 to 50°C (32 to 122°F)
Relative Humidity : 0 to 90% @ 30°C,
0 to 80% @ 40°C, 0 to 70% @ 50°C,
noncondensing
Regulatory2100Q : Meets EPA Method 180.1
2100Qis : Meets ISO 7027
Storage
Conditions
-40 to 60°C (-40 to 140°F),
instrument only
Light
Source
2100Q : Tungsten filament lamp
2100Qis: Light-emitting diode (LED) @ 860 nm
LanguagesEnglish, French, German, Italian, Spanish,Portuguese (BR), Portuguese (PT), Bulgarian,Chinese, Czech, Danish, Dutch, Finnish, Greek,
Hungarian, Japanese, Korean, Polish, Romanian,Russian, Slovenian, Swedish, Turkish
Range0 to 1000 NTU (FNU)InterfaceOptional USB
Accuracy± 2 % of reading plus stray
light from 0 to 1000 NTU
Instrument
Enclosure Rating
IP67 (closed lid, battery
compartment excluded)
Repeatability± 1% of reading, or 0.01 NTU (FNU),
whichever is greater
Protection
Class
Power Supply : Class II
Resolution0.01 NTU on lowest rangeCertificationCE certified
Stray Light<0.02 NTU (FNU)Sample Required15 mL (0.3 oz.)
Signal
Averaging
Selectable on/offSample
Cells
60 x 25 mm (2.36 x 1 in.)
borosilicate glass with screw cap
DetectorSilicon photovoltaicDimensions22.9 x 10.7 x 7.7 cm , (9.0 x4.2 x 3.0 in.)
Reading Modes
(user selectable)
Normal (Push to Read)
Signal Averaging
Rapidly Settling Turbidity
Weight527 g (1.16 lb) without batteries 618 g
(1.36 lb) with four AA alkaline batteries
Data Logger500 records
Warranty
1
Power
Requirement
110-230 Vac, 50/60 Hz
(with Power or USB+Power Module)
4 AA alkaline batteries Rechargeable NiMH (for use with USB+Power Module)

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Key Features
On-Screen Assisted Calibration and Verification
The 2100Q gives you confidence that your results are accurate, without having to read long manuals for calibration and verification instructions. All the core measurement information is on a single screen.

Rapidly Settling Turbidity™ (RST) Mode
At the request of our customers, Hach has developed an innovative solution to alleviate the uncertainty caused by changing turbidity readings in samples that quickly settle. The 2100Q’s RST reading mode uses an exclusive algorithm that reverse calculates and continuously updates a calculated value of turbidity to a point in time when the sample begins to settle out of solution based upon the accumulated trend of the measured values. This results in values that are more accurate and repeatable than those obtained using traditional smoothing techniques, such as averaging.

Customize Power and Connectivity with Flexible Modules

USB+Power Module 

(Prod. No. LZV813)


  • Line power: 110 - 230Vac, 50/60 Hz                      

  • Charges NiMH batteries

  • Transfers data to computer or printer

  • Enables firmware updates

Power Only Module 

(Prod. No. LZV804)


  • Line power: 110 - 230Vac, 50/60 Hz

Ordering Information

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and on CD-ROM), quick start guide, silicone oil and oiling cloth.

  • 2100Q-01     2100Q Portable Turbidimeter (meets EPA method 180.1)

  • 2100QIS-01     2100Qis Portable Turbidimeter (meets ISO 7027)


Hach 2100Q and 2100Qis Portable Turbidimeters

Optional Accessories
Replacement Parts
LZV813
USB+Power Module2971205StablCal ampule calibration kit, 2100Q
(includes: universal power supply,
USB cables, instruction sheet)
296170110 NTU Verification Standard
LZV804Power Module (includes : universal power
supply, instruction sheet)
126936Silicone Oil, 15 mL
2960100Citizen PD-24 Printer Package2971507Insert, molded bottom,
2100Q carrying case
2971304Battery, NiMH AA, pk/4 4397500
Degassing Kit
4707600Sample Cell Oiling Cloth
4397510Sample Filtration and
Degassing Kit
24347061"glass sample cell (10ml )
w / cap (Turb) pkg/6
2971210StablCal 100 mL
calibration kit, 2100Q
2971500Carrying case for 2100Q
(includes insert)
2971200StablCal 500 mL
calibration kit, 2100Q
4653900Lamp assembly
2464105Gelex Secondary Standard Set1938004Battery set, 4x AA alkaline batteries

Hach 2100Q and 2100Qis Portable Turbidimeters


Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di : 

HACH 2100Q Manual




HACH 2100Q Manual

Easiest calibration and verification with accurate results every time.

The Hach 2100Q and 2100Qis Portable Turbidimeters offer unsurpassed ease of use and accuracy in turbidity measurement. Only Hach offers this combination of advanced features including assisted calibration, simplified data transfer, and innovative measurement techniques that give you accurate results every time.

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Easy On-Screen Assisted Calibration and Verification


The 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal™ calibration offer a simplified solution for low level measurements.

Convenient Data Logging


Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.

Simple Data Transfer



Customizable power and connectivity modules provide smooth data transfer and flexibility. Optional USB+Power Module allows data download to any computer via USB port, providing superior data integrity and availability.


Optical System for Precision in the Field


The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, allowing you to achieve laboratory-grade performance on a wide range of samples, even under di@cult site conditions.


Accuracy for Rapidly Settling Samples


The innovative Rapidly Settling Turbidity™ mode provides accurate, repeatable measurements for di@cult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Two Models forpecific USEPA Requirements


The 2100Q Turbidimeter is compliant with USEPA Method 180.1 design criteria. The 2100Qis Turbidimeter is compliant with ISO 7027 design criteria.

HACH 2100Q Manual

Hach 2100Q and 2100Qis Portable Turbidimeters
Specification
Measurement
Method
Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) to the transmitted light scatter signal.Operating
Conditions
Temperature : 0 to 50°C (32 to 122°F)
Relative Humidity : 0 to 90% @ 30°C,
0 to 80% @ 40°C, 0 to 70% @ 50°C,
noncondensing
Regulatory2100Q : Meets EPA Method 180.1
2100Qis : Meets ISO 7027
Storage
Conditions
-40 to 60°C (-40 to 140°F),
instrument only
Light
Source
2100Q : Tungsten filament lamp
2100Qis: Light-emitting diode (LED) @ 860 nm
LanguagesEnglish, French, German, Italian, Spanish,Portuguese (BR), Portuguese (PT), Bulgarian,Chinese, Czech, Danish, Dutch, Finnish, Greek,
Hungarian, Japanese, Korean, Polish, Romanian,Russian, Slovenian, Swedish, Turkish
Range0 to 1000 NTU (FNU)InterfaceOptional USB
Accuracy± 2 % of reading plus stray
light from 0 to 1000 NTU
Instrument
Enclosure Rating
IP67 (closed lid, battery
compartment excluded)
Repeatability± 1% of reading, or 0.01 NTU (FNU),
whichever is greater
Protection
Class
Power Supply : Class II
Resolution0.01 NTU on lowest rangeCertificationCE certified
Stray Light<0.02 NTU (FNU)Sample Required15 mL (0.3 oz.)
Signal
Averaging
Selectable on/offSample
Cells
60 x 25 mm (2.36 x 1 in.)
borosilicate glass with screw cap
DetectorSilicon photovoltaicDimensions22.9 x 10.7 x 7.7 cm , (9.0 x4.2 x 3.0 in.)
Reading Modes
(user selectable)
Normal (Push to Read)
Signal Averaging
Rapidly Settling Turbidity
Weight527 g (1.16 lb) without batteries 618 g
(1.36 lb) with four AA alkaline batteries
Data Logger500 records
Warranty
1
Power
Requirement
110-230 Vac, 50/60 Hz
(with Power or USB+Power Module)
4 AA alkaline batteries Rechargeable NiMH (for use with USB+Power Module)


Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure


Key Features
On-Screen Assisted Calibration and Verification
The 2100Q gives you confidence that your results are accurate, without having to read long manuals for calibration and verification instructions. All the core measurement information is on a single screen.

Rapidly Settling Turbidity™ (RST) Mode
At the request of our customers, Hach has developed an innovative solution to alleviate the uncertainty caused by changing turbidity readings in samples that quickly settle. The 2100Q’s RST reading mode uses an exclusive algorithm that reverse calculates and continuously updates a calculated value of turbidity to a point in time when the sample begins to settle out of solution based upon the accumulated trend of the measured values. This results in values that are more accurate and repeatable than those obtained using traditional smoothing techniques, such as averaging.

Customize Power and Connectivity with Flexible Modules

USB+Power Module 

(Prod. No. LZV813)


  • Line power: 110 - 230Vac, 50/60 Hz                      

  • Charges NiMH batteries

  • Transfers data to computer or printer

  • Enables firmware updates

Power Only Module 

(Prod. No. LZV804)


  • Line power: 110 - 230Vac, 50/60 Hz

Ordering Information

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and on CD-ROM), quick start guide, silicone oil and oiling cloth.

  • 2100Q-01     2100Q Portable Turbidimeter (meets EPA method 180.1)

  • 2100QIS-01     2100Qis Portable Turbidimeter (meets ISO 7027)

HACH 2100Q Manual

Optional Accessories
Replacement Parts
LZV813
USB+Power Module2971205StablCal ampule calibration kit, 2100Q
(includes: universal power supply,
USB cables, instruction sheet)
296170110 NTU Verification Standard
LZV804Power Module (includes : universal power
supply, instruction sheet)
126936Silicone Oil, 15 mL
2960100Citizen PD-24 Printer Package2971507Insert, molded bottom,
2100Q carrying case
2971304Battery, NiMH AA, pk/4 4397500
Degassing Kit
4707600Sample Cell Oiling Cloth
4397510Sample Filtration and
Degassing Kit
24347061"glass sample cell (10ml )
w / cap (Turb) pkg/6
2971210StablCal 100 mL
calibration kit, 2100Q
2971500Carrying case for 2100Q
(includes insert)
2971200StablCal 500 mL
calibration kit, 2100Q
4653900Lamp assembly
2464105Gelex Secondary Standard Set1938004Battery set, 4x AA alkaline batteries

HACH 2100Q Manual

Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :