Item | Specifications |
General Parameters | Power Supply | AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz (Optional) |
Size (L*W*H) | 950*645*(1250-11450) mm |
Maximum heater output power (220VAC) | Air chamber heater: 330W; |
Water tank heater: 155W |
Auxillary network power output | AC 220V / 50Hz, Both maximum permissible currents are 220V 1.5A |
Heater indication | 0-100%, 10% increasing amount |
Temperature control mode | Bed temperature mode ; The skin temperature mode |
Bed temperature control | 25.0 - 37.0°C; |
temperature range | 37.1 - 39.0°C (Span Mode) |
Skin temperature sensor temperature display range | 5.0 - 65.0°C |
Heating time | < 50min |
Temperature variability | < 0.5°C |
Temperature uniformity (mattress in horizontal position) | < 0.8°C |
Temperature uniformity (mattress in tilted position) | < 1.0°C |
Difference between average incubator temperature and control temperature | < 1.5°C |
Skin temperature sensor accuracy | +0.3°C |
Humidity Control | The running time of the tank after it is filled with distilled water | Humidity below 70%RH, at least 24h |
Water tank capacity | 1500ml |
Humidity display range | 0%RH - 99%RH |
Humidity control range | CAH%RH - 90%RH(1% per adjustment) |
Humidity control accuracy | +100% |
Oxygen Concentration Control | Oxygen concentration display range | 0% - 99% |
Oxygen concentration display resolution | 1% |
Oxygen concentration control accuracy | +5% oxygen volume concentration |
Oxygen concentration setting range | 21% - 60% (1% per adjustment) |
Oxygen sensor service life | The maximum use time is 10000h at 100 % oxygen concentration |
Transport Storage | Temperature | -2°C - +55°C |
Atmospheric pressure range | 500hPa - 1060hPa |
Relative humidity | < 93% RH |
Packing Size / Gross Weight | Base packing size: 1200*800*870mm 50kg |
Body packing size: 1100*710*855mm 60kg |
The Work Environment | Relative humidity | 30%RH - 75%RH |
The environment temperature | +20°C - + 30°C |
Pressure range | 700hPa - 1060hPa |
Service altitude | < 2000m |
Over voltage category | II |
Pollution levels | 2 |
Ambient air velocity | < 0.3m/s |
Other Indicator | Environmental noise in incubator baby compartment | No more than 55dB(A) at stable temperature |
Carbon dioxide concentration in the infant compartment | A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization |
The velocity of air flow over a baby's mattress | < 0.35m/s |
General Alarm | Power off alarm, Fan alarm, sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm |
The System Alarm | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault, Humidity heating system fault |
Flickr Images
Text Widget
Laporkan Penyalahgunaan
Pengikut
Cari Blog Ini
Blog Archive
Pages
About Us
Industrial Testing
Mineral/Civil Material Testing