Tawk.to

PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER

 



No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER

PT. Mora Anugerah Berkat adalah perusahaan yang menyediakan berbagai alat uji test (tesing machine) untuk berbagai macam industri, kami sudah berpengalaman menyediakan dan mensupply berbagai alat uji di seluruh indonesia dengan dukungan tenaga teknisi yang sudah berpengalaman di bidang nya.


No.148-HD HEAT DISTORTION TESTER
Specification
Stations3, 4 or 6 Stations (3 kinds)
Temperature RangeMax. 300 °C (Oil Bath)
Heat-Up Speed120 ± 10 °C/hr, 50 ± 5 °C/hr
Bending Stress1.80 MPa and 0.45 MPa
Weight
Load
DTUL : Choose 2 types from Initial 76.5 gf to Max. 3,210 gf
Option VICAT: 10 ± 0.2 N, 50 ± 1 N ;
Ball Pressure: 0.4 to 20 N
Displacement
Measurement
Differential Transformer :
Scale 1/1,000 mm ; Stroke 0 to ± 2 mm
Pressure
Foot
DTUL: R 3.0 ± 0.2 mm
Option VICAT: 1.000 ± 0.015 mm2
Option Ball Pressure: φ5 mm
Support Length64 ± 1 mm, 100 ± 2 mm
Refrigerating
Device
Water Circulating System
(Option: Self Contained Refrigerator) :
*When High Temperature cooling or Test Start Temperature 20 to 23 °C
Churning DevicePropeller Type
3 and 4 Stations : 2 Propellers
6 Stations : 3 Propellers
SoftwareWindows Compatible
AccessoriesPressure Foot Adjustment, Specimen Holder
OptionSilicon Oil, Safety Cover, Simultaneous Loading Device (Standard for No.148-HDA), Borosilicate Glass
Power SourceAC 200 V, 1-Phase, 30 to 40 A, 50/60 Hz
Dimensions / Weight 
(Approx.)
W700 to 1,000 × D500 × H1,300 mm:
170 to 220 kg

 =========================================

No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER
=========================================


No.148-HDA HEAT DISTORTION TESTER (FULLY AUTOMATIC)
Specification
Stations3 or 6 Stations (2 kinds)
Temperature RangeMax. 300 °C (Oil Bath)
Heat-Up Speed120 ± 10 °C/hr and 50 ± 5 °C/hr
Bending Stress1.80 MPa, 0.45 MPa
Weight LoadDTUL: Choose 2 types from Initial 76.5 gf to Max. 3,210 gf
Option VICAT: 10 ± 0.2 N, 50 ± 1 N
Option Ball Pressure: 0.4 to 2.0 N
Displacement
Measurement
Differential Transformer :
Scale 1/1,000 mm, Stroke 0 to ± 2 mm
Pressure
Foot
DTUL: R 3.0 ± 0.2 mm
Option VICAT: 1.000 ± 0.015 mm2
Option Ball Pressure: φ5 mm
Support Length64 ± 1 mm, 100 ± 2 mm (Standard)
Refrigerating
Device
Water Circulating System (Option: Self Contained Refrigerator) :
*When High Temperature cooling or Test Start Temperature 20 to 23 °C
Churning
Device
Propeller Type 3 and 4 Stations : 2 Propellers
6 Stations: 3 Propellers
Test
Specimens
40 pcs × 3 Cassettes (Total 120 pcs)
*When T10 mm
SoftwareWindows Compatible
AccessoriesPressure Foot Adjustment, Specimen Holder
OptionSilicon Oil, Safety Cover, Simultaneous Loading Device (Standard for No.148-HDA), Borosilicate Glass
Power SourceAC 200 V, 3-Phase, 30 A, 50/60 Hz
Air Source0.5MPa or More
Dimensions / Weight 
(Approx.)
W930 to 1,150 × D600 × H1,300 mm,
350 to 400 kg

=========================================

No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER
=========================================


No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER
Specification
Stations3 Stations
Temperature
Range
Max. 500 °C
(Air Chamber, Nitrogen Gas Filling Device Attached)
Heat-Up Speed120 ± 10 °C/hr, 50 ± 5 °C/hr
Bending Stress1.80 MPa, 0.45 MPa
Weight LoadDTUL: Choose 2 types from Initial 76.5 gf to
Max. 3,210 gf
Option VICAT: 10 ± 0.2 N, 50 ± 1 N
Option Ball Pressure: 0.4 to 2.0 N
Displacement
Measurement
Differential Transformer :
Scale 1/1,000 mm, Stroke 0 to ± 2 mm
Pressure
Foot
DTUL: R 3.0 ± 0.2 mm
Option VICAT: 1.000 ± 0.015 mm2
Option Ball Pressure: φ5 mm
Support Length64 ± 1 mm, 100 ± 2 mm (Standard)
RefrigeratingFan type (Air Fan Cooling), 3 Fans,
DeviceCarbon Gas Injection Cooling System
Churning DevicePropeller type, 3 propellers
SoftwareWindows Compatible
AccessoriesPressure Foot Adjustment, Specimen Holder
Option
Safety Cover, Simultaneous Loading Device,
Borosilicate Glass
Power SourceAC 200 V, 1-Phase, 30 A, 50/60 Hz
Dimensions / Weight 
(Approx.)
W1,100 × D650 × H1,500 mm,
250 kg

PT. Mora Anugerah Berkat (M.A.B) adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan uji  industrial testing equipment seperti No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER , kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : Yasuda Seiki, Qualitest, Drick Inst, Testex  dan lain - lain.Kami juga menyediakan Jasa Perbaikan (SERVICE)Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

No.148-HD500 HIGH TEMPERATURE HEAT DISTORTION TESTER

0 Komentar: