PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

Falling Dart Impact Tester [DRK135A]

 



   

Falling Dart Impact Tester [DRK135A]

Jika anda membutuhkan atau mencari No.220 Dart Impact Test untuk kebutuhan alat uji anda, PT. Mora Anugerah Berkat merupakan perusahaan yang menyediakan kebutuhan alat uji material testing khususnya untuk industri seperti dibidang plastic, rubber, tape/film, polymer,ink, coating, cat,packaging, pulp/paper dan masih banyak lagi,berikut ini yang kami tawarkan adalah No.220 Dart Impact Test , untuk spesifikasi adalah sebagai berikut.

Product Details

DRK135A Falling Dart Impact Tester is applicable in the impact result and energy measurement of the falling dart from a certain height against plastic films and sheets with thickness less than 1mm, which would result in 50% tested specimen failure.

Product Features :

1. Mechanical modelling novel, considerate operation design;
2. Comply with international standard and national standard both;
3. Two test methods integration: A & B. easy to use;
4. Electric gripped sample;
5. Micro computer processing experimental data, the intelligent experimental process, greatly improving the work efficiency;
6. CLICK HERE : DRK135A Falling Dart Impact Tester Brochure

Product Application

It is applicable to test the impact resistance properties of plastic film, sheet, composite film, with thickness less than 1mm, such as plastic wrap, stretch film, PET sheet, different food packaging bags, heavy bags, aluminum foil, aluminum compound packing film, paper and cardboard, etc.

Technical Standard

At the beginning of the test, choose test method, and estimate an initial mass and Δm. Start test. If the first specimen fails, decrease the mass of the falling dart by decreasing weight of Δm. If the first specimen is not a failure, add the mass of the falling dart by increasing weight of Δm. Test as the same. In brief, increase or decrease the Δm according to whether the former specimen is a failure or not. After 20 specimens, calculate the total number of failure specimens N. If N equals to 10, test over. If N is less than 10, add specimen and continue to test until N is equal to 10. If N is more than 10, add specimen and continue the test until the number of non-failure specimen is 10. Then the tester calculates the test results automatically according to special formula.

It complies with standards ASTM D1709, ISO 7765, JIS K7124, GB 9639.


DRK135 - Falling Dart Impact Tester
Specification
ITEMParameter
Test MethodA,B (Optional)
Test
Range
Method A : 50 - 2000g
Method B : 300 - 2000g
Test Accuracy0.1g (0.1J)
Speciment Size> 150 mm x 150 mm
PowerAC 220V ; 50 Hz
Net Weight60 Kg


Main fixtures
Standard : method A configuration, mini-printer, communication cable
Optional : method B configuration, mini-printer, communication cable

PT. Mora Anugerah Berkat (M. A. B) adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan industrial material testing equipment seperti Falling Dart Impact Tester [DRK135A], kami juga menyediakan peralatan yang sudah teruji dan sesuai dengan standard seperti ASTM, JIS dan lain-lain ; kami juga menyediakan berbagai brand / merk internasional dari USA, Eropa dan China,produk internasional yang kami supply / tawarkan seperti : Yasuda Seiki, Qualitest, Toyoseiki, Drick Instrument, Cometech,Testex Instrument dan lain – lain.