GENESYS 30 Visible Spectrophotometer Manual
Get high precision and functionality in a simple yet sophisticated visible spectrophotometer. The Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer performs both basic and complex analyses for educational or industrial use. Its intuitive design allows students and teachers to focus on scientific data and concepts rather than on learning how to use the instrument. In the lab, technicians of all levels working in routine QA/QC applications can easily obtain credible results to confirm quality or inform next steps. Results can be reported quickly as digital or printed data.
GENESYS 30 Visible Spectrophotometer Manual
The GENESYS 30 visible spectrophotometer brings you intuitive design, a high definition color screen, fast and accurate measurements, and convenient data reporting. It is the ideal instrument for any user, whether a novice student or an experienced lab associate.
Product Features:
Entirely new industrial design for better usability
High definition 5-inch color screen with rubberized push-button keypad for easy navigation
Single cell measurement with removable, washable sample compartment liner
Standard cell holder for 10mm cuvettes and optional holders for other cell types including test-tubes
New onboard software UI; Thermo Scientific™ VISIONlite PC software is optional
Excellent snap-on thermal printer available
Three-year warranty and skilled technical support
Meets curriculum topics for:
Lab associate benefits:
Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
GENESYS 30 Visible Spectrophotometer Manual
Catalog Number | GENESYS 30 Visible Spectrophotometer |
840-277000 |
Detector Type | Silicon Photodiode |
Display | 5 in. diagonal, 32 bit color display, 800 x 480 pixels |
Photometric Accuracy Instrument | ± 0.002A (0 - 0.3A) 0.5 % of ABS reading (0.301A - 2.5A) |
Printer | Thermal printer accessory with 80mm width paper |
Wavelength Accuracy | ± 2nm |
Baseline Flatness | < 0.003A 325nm – 1000nm smoothed |
Compartments | - Accessible from top, front or side
- Able to accommodate cells up to 100mm pathlength
- Available accessory for test-tubes up to 25mm diameter and 150mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - USB-A on front face supports flash memory devices for method and data storage.
- USB-B on side supports connection to a Windows™ computer running optional remote control software.
|
Description | GENESYS 30 Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5 cm x 38.5 cm x 19.5 cm |
Drift | < 0.002A/Hr At 500nm after 2hr warmup. Typical < 0.004A/hr after 1hr warmup |
Electrical Requirements | External AC to DC converter. Voltage and Hz selected automatically, 100 - 250 Volts, 50 - 60 Hz |
Keypad | Tactile rubber 23 keys with numeric keypad |
Lamp | 1000 Hrs typical service life |
Languages | English, Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Noise | ≤ 0.001A at 0A ≤ 0.001A at 1A ≤ 0.002A at 2A RMS at 500 nm. 60 consecutive measurements |
Optical Design | Single beam |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Photometric Range | -3A to +3A |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A @546nm |
Spectral Bandwidth | 5 nm |
Stray Light | < 0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Wavelength Data Interval | 1nm |
Wavelength Range | 325 nm – 1100 nm |
Wavelength Repeatability | < ±1nm |
Wavelength Scan Speed | Automatic – up to 1200 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
=========
Catalog Number | GENESYS 40 Visible Spectrophotometer |
840-297000 |
Optical Design | Dual beam |
Spectral Bandwidth | 5 nm |
Wavelength Range | 325 nm – 1100 nm |
Detector Type | Dual Silicon Photodiodes |
Display | 7 - Inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ± 0.002A at 0.5A ; ± 0.004A at 1.0A ; ±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ± 0.5 nm |
Baseline Flatness | ± 0.005A |
Compartments | - Accessible from top, front or side Able to accommodate cells up to 100mm cells
- Available accessory for test tubes up to 25 mm diameter and 150 mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
- Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
|
Description | GENESYS 40 Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0010A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad | Touchscreen |
Lamp | Tungsten-Halogen (>1000 hours) |
Noise | (RMS at 500 nm 60 consecutive measurements) : ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Dual Beam |
Photometric Display | -3A to +5A |
Photometric Range | -3A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 5 nm |
Stray Light | <0.05%T at 340 nm and 400 nm |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range | 325 nm – 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Automatic – up to 1800 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
=========
Catalog Number | GENESYS 50 UV-Vis Spectrophotometer |
840-298000 |
Optical Design | Dual Beam |
Spectral Bandwidth | 2 nm |
Wavelength Range | 190 nm – 1100 nm |
Detector Type | Dual Silicon Photodiodes |
Display | 7 - inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ±0.5 nm |
Baseline Flatness | ±0.002A |
Compartments | - Accessible from top, front or side Able to accommodate cells up to 100mm cells
- Available accessory for test tubes up to 25 mm diameter and 150 mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
- Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor,available Print via USB, Ethernet or Wi-Fi USB adaptor available
|
Description | GENESYS 50 UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) < 0.0005A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad | Touchscreen |
Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Dual beam |
Photometric Display | -3A to +5A |
Photometric Range | -2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 2 nm |
Stray Light | < 1.0%T 198 nm (KCl) , < 0.05%T at 220 nm (NaI), < 0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range | 190 nm - 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast - up to 1600 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
=========
Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan laboratorium untuk seperti GENESYS 30 Visible Spectrophotometer Manual , kami juga menyediakan peralatan yang sudah teruji dan sesuai dengan ASTM,kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : Thermo Scientific (Thermo Fisher), Hach, Benchmark Scientific, Horiba, Biolab dan lain - lain.
GENESYS 30 Visible Spectrophotometer Manual
Kami juga menyediakan Jasa Perbaikan (SERVICE),Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda
PT. Mora Anugerah Berkat (M.A.B)
Alamat : Jl. Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
Phone : 021 7345.7064 / 7366.0160
Mobile: 0812.8140.0749 / 0812.8770.5470
Chat : Whats App, Line, WeChat, Telegram
Website : www.moraanugerah.id - www.moraanugerah.com
Email : info@moraanugerah.com - info@moraanugerah.id -marketing_div@moraanugerah.com