Tawk.to

PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

Jual GENESYS UV/Vis Spectrophotometers di Jakarta

Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes.


Jual GENESYS UV/Vis Spectrophotometers di Jakarta 

The GENESYS 50 is a dual beam UV-Vis spectrophotometer in a single-cell configuration that meets all of the specifications for critical quality control applications and precise chemical measurements. The GENESYS 40 Dual Beam Vis Spectrophotometer is a visible spectral region version in this instrumental class. Both  feature data resolution from 0.2 nm to 5 nm.

Click Here : Thermo Scientific GENESYS 40/50 UV/Vis Spectrophotometer Catalog

DescriptionGENESYS 30GENESYS 40GENESYS 140
Optical DesignSingle BeamDouble Beam
Spectral Bandwidth5 nm
Light Source (Typical Lifetime)Tungsten-Halogen (>1000 hours)
DetectorSilicon PhotodiodeDual Silicon Photodiodes
Wavelength
Range325–1100 nm
Accuracy± 2 nm± 0.5 nm
Repeatability< ± 1 nm< ± 0.2 nm
Scan SpeedAutomatic - up to 1200 nm/minAutomatic - up to 1800 nm/min
Data Resolution1 nm0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Photometric
Range–3A to +3A–3A to +3.5A
Display–3A to +3A, 0 to 200 000 %T,
0 to 9 999 999 C
–3A to +5A
Accuracy± 0.002A (0 - 0.3A) 0.5 % of
ABS reading (0.301A - 2.5A)
± 0.002A at 0.5A
± 0.004A at 1.0A
± 0.008A at 2.0A
Repeatability1± 0.002 A± 0.001A at 1A
Noise2≤ 0.001A at 0A
≤ 0.001A at 1A
≤ 0.002A at 2A
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Drift3< 0.002A/Hr< 0.0010A/Hr
Stray Light< 0.1%T at 340 nm and 400 nm< 0.05%T at 340 nm and 400 nm
Baseline Flatness< 0.003A< 0.005A
Display5-inch diagonal, 32-bit color display,
800 × 480 pixels
7-inch color touchscreen,
fixed, high definition, 800 × 1280 pixels
7-inch color touchscreen, tiltable,
high definition, 800 × 1280 pixels
KeypadTactile rubber 23 keys with
numeric keypad
Touchscreen
Sample
Compartment
• Accessible from top, front or side
• All platforms can accommodate 100 mm cells
• Available accessory for test-tubes up to 25 mm diameter & 150 mm height
• Removable, washable sample compartment liner with magnetic placement
and hold-down
Accommodates (optional):
• 8-position cell changer
• 4-position cell changer (long path cells)
• Peltier thermostatted cell holder (20–60 °C)
• Sipper accessory
PrinterSnap-on printer available
Connectivity
• USB-A on front face supports flash memory devices for method
and data storage
• USB-B on side supports connection to a Windows computer running
optional remote control software; export data to PC via USB
• Single USB-A supports flash
memory devices for method and data storage
• Duplex USB-A supports connection to a
Windows computer running optional remote
control software, keyboard, mouse
• Export data to network or PC via Ethernet or Wi-Fi
• Print via USB, Ethernet or Wi-Fi
LanguagesEnglish (Available soon: Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai)
Dimensions35.5 × 38.5 × 19.5 cm (L × W × H)
Weight7.5 kg
Power RequirementsExternal AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz.
WarrantyI (one) Year

Jual GENESYS UV/Vis Spectrophotometers di Jakarta
 

DescriptionGENESYS 50GENESYS 150BioMate 160GENESYS 180
Optical DesignDouble Beam
Spectral Bandwidth2 nm
Light Source (Typical Lifetime)Xenon Flash Lamp (>5 years typical, 3 years guaranteed)
DetectorDual Silicon Photodiodes
Wavelength
Range190–1100 nm
Accuracy± 0.5 nm
Repeatability< ± 0.2 nm
Scan SpeedSlow, medium and fast (up to 1600 nm/min)
Data Resolution0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm0.1 nm, 0.2 nm, 0.5 nm,
1 nm, 2 nm, 5 nm
Photometric
Range–2A to +3.5A
Display–3A to +5A
Accuracy± 0.002A at 0.5A
± 0.004A at 1.0A
± 0.008A at 2.0A
Repeatability1± 0.001A at 1A
Noise2
Drift3<0.0005A/Hr
Stray Light< 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2)
Baseline Flatness± 0.002
Display7-inch color touchscreen,
fixed, high definition, 800 × 1280 pixels
7-inch color touchscreen, tiltable, high definition, 800 × 1280 pixels
KeypadTouchscreen
Sample
Compartment
• Accessible from top, front or side
• Able to accommodate cells up to 100 mm pathlength
• Available accessory for test-tubes up to 25 mm diameter and 150 mm height
• Removable, washable sample compartment liner with magnetic placement and hold-down
Accommodates (optional):
• 8-position cell changer
• 4-position cell changer (long pathcells)
• Peltier thermostatted cell holder (20–60 °C)
• Sipper accessory
• Fiber optic probe coupler
• 8-position cell changer
(standard) Also
accommodates (optional):
• 4-position cell changer
(long path cells)
• Peltier thermostatted
cell holder (20–60 °C)
• Sipper accessory
• Fiber optic probe coupler
PrinterSnap-on printer available
Connectivity• Single USB-A supports flash memory devices for method and data storage
• Duplex USB-A supports connection to a Windows computer running optional remote control software, keyboard, mouse
• Export data to network or PC via Ethernet or Wi-Fi
• Print via USB, Ethernet or Wi-Fi
LanguagesEnglish (Available soon: Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai)
Dimensions35.5 × 38.5 × 19.5 cm (L × W × H)
Weight7.5 Kg
Power RequirementsExternal AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz.
Warranty1 (One) Years

PT. Mora Anugerah Berkat sudah berpengalaman menyediakan dan mensupply alat instrument/analitik dari Thermo Scientific Genesys Spectrophotometer,kami juga menyediakan berbagai aksessoris dan sparepart dari Genesys Spectrophotometry dan mensupport layanan seperti re-training penggunaan spectrophotometer genesys, jasa perawatan (Maintenance), Jasa Perbaikan (Service) dan mensupport (membantu) untuk kalibrasi dan lain - lain jangan ragu menghubungi kami.

Jual GENESYS UV/Vis Spectrophotometers di Jakarta 


Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di : 