Tawk.to

PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

Jual GENESYS 30 Visible Spectrophotometer Cat No.840-277000 di Kota Pematangsiantar

Get high precision and functionality in a simple yet sophisticated visible spectrophotometer. The Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer performs both basic and complex analyses for educational or industrial use. Its intuitive design allows students and teachers to focus on scientific data and concepts rather than on learning how to use the instrument. In the lab, technicians of all levels working in routine QA/QC applications can easily obtain credible results to confirm quality or inform next steps. Results can be reported quickly as digital or printed data.


Jual GENESYS 30 Visible Spectrophotometer Cat No.840-277000 di Kota Pematangsiantar

The GENESYS 30 visible spectrophotometer brings you intuitive design, a high definition color screen, fast and accurate measurements, and convenient data reporting.  It is the ideal instrument for any user, whether a novice student or an experienced lab associate.

Click Here : Thermo Scientific GENESYS 30 Visible Spectrophotometer

Product Features :

  • Entirely new industrial design for better usability

  • High definition 5-inch color screen with rubberized push-button keypad for easy navigation 

  • Single cell measurement with removable, washable sample compartment liner 

  • Standard cell holder for 10mm cuvettes and optional holders for other cell types including test-tubes

  • New onboard software UI; Thermo Scientific™ VISIONlite PC software is optional 

    • Data any way you want it 

    • USB data export in a text format that’s easy to read and process

  • Excellent snap-on thermal printer available

  • Three-year warranty and skilled technical support 

Meets curriculum topics for: 

  • Single wavelength

  • Scanning

  • Beer’s Law

  • Colorimetry/colorimetric analysis

  • Quantitative analysis

Lab associate benefits: 

  • Higher data confidence with 6-point quant plus concentration mode 

  • Multiple local language choices 

Jual GENESYS 30 Visible Spectrophotometer Cat No.840-277000 di Kota Pematangsiantar


Specification


Click Here : Thermo Scientific GENESYS 30 Visible Spectrophotometer


Catalog Number
GENESYS 30 Visible Spectrophotometer
840-277000
Detector TypeSilicon Photodiode
Display5 in. diagonal, 32 bit color display, 800 x 480 pixels
Photometric Accuracy
Instrument
±0.002A (0 - 0.3A)
0.5% of ABS reading (0.301A - 2.5A)
PrinterThermal printer accessory with 80 mm width paper
Wavelength Accuracy± 2nm
Baseline Flatness<0.003A
325nm – 1000nm smoothed
Compartments:) Accessible from top, front or side
:) Able to accommodate cells up to 100mm pathlength
:) Available accessory for test-tubes up to
   25mm diameter and 150mm height
:) Removable, washable sample compartment liner
   with magnetic placement and hold-down
Connections:) USB-A on front face supports flash memory devices
   for method and data storage
:) USB-B on side supports connection to a Windows™     computer
   running optional remote control software.
DescriptionGENESYS 30 Visible Spectrophotometer
Dimensions
(L x W x H)
35.5cm x 38.5cm x 19.5cm
Drift<0.002A/Hr
At 500nm after 2hr warmup.
Typical <0.004A/hr after 1hr warmup
Electrical
Requirements
External AC to DC converter.
Voltage and Hz selected automatically,
100 - 250 Volts, 50 - 60 Hz
KeypadTactile rubber 23 keys with numeric keypad
Lamp1000 Hrs typical service life
LanguagesEnglish, Spanish, German, French,
Italian, Portuguese, Russian,Chinese,
Japanese, Korean, Thai, Arabic
Noise≤0.001A at 0A
≤0.001A at 1A
≤0.002A at 2A
RMS at 500nm. 60 consecutive measurements
Optical DesignSingle beam
Photometric Display-3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C
Photometric Range-3A to +3A
Photometric
Repeatability
± 0.002 A
Measured at 1.0 A @546nm
Spectral Bandwidth5 nm
Stray Light<0.1%T at 340nm and 400nm
Measured using glass cutoff filters or NaNO2 at 340nm
Wavelength Data Interval1nm
Wavelength Range325nm – 1100nm
Wavelength Repeatability< ±1nm
Wavelength Scan SpeedAutomatic – up to 1200nm/min
Weight (Metric)7.5kg
Unit SizeEach

PT. Mora Anugerah Berkat sudah berpengalaman menyediakan dan mensupply alat instrument/analitik dari Thermo Scientific Genesys Spectrophotometer,kami juga menyediakan berbagai aksessoris dan sparepart dari Genesys Spectrophotometry dan mensupport layanan seperti re-training penggunaan spectrophotometer genesys,jasa perawatan (Maintenance),Jasa Perbaikan (Service) dan mensupport (membantu) untuk kalibrasi dan lain - lain jangan ragu menghubungi kami.