Tawk.to

PT.Mora Anugerah Berkat adalah perusahaan penyedia alat – alat laboratorium, alat laboratorium yang kami sediakan meliputi : general laboratorium equipment,medical equipment (alat kesehatan), environmental (alat uji lingkungan), chemical/reagent consumable,mineral/civil material testing dan kalibrasi.

Hach 2100Q and 2100Qis Portable Turbidimeters




Hach 2100Q and 2100Qis Portable Turbidimeters


Easiest calibration and verification with accurate results every time.

The Hach 2100Q and 2100Qis Portable Turbidimeters offer unsurpassed ease of use and accuracy in turbidity measurement. Only Hach offers this combination of advanced features including assisted calibration, simplified data transfer, and innovative measurement techniques that give you accurate results every time.

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Easy On-Screen Assisted Calibration and Verification


The 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal™ calibration offer a simplified solution for low level measurements.

Convenient Data Logging


Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.

Simple Data Transfer



Customizable power and connectivity modules provide smooth data transfer and flexibility. Optional USB+Power Module allows data download to any computer via USB port, providing superior data integrity and availability.


Optical System for Precision in the Field


The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, allowing you to achieve laboratory-grade performance on a wide range of samples, even under di@cult site conditions.


Accuracy for Rapidly Settling Samples


The innovative Rapidly Settling Turbidity™ mode provides accurate, repeatable measurements for di@cult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Two Models forpecific USEPA Requirements


The 2100Q Turbidimeter is compliant with USEPA Method 180.1 design criteria. The 2100Qis Turbidimeter is compliant with ISO 7027 design criteria.


Hach 2100Q and 2100Qis Portable Turbidimeters

Hach 2100Q and 2100Qis Portable Turbidimeters
Specification
Measurement
Method
Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) to the transmitted light scatter signal.Operating
Conditions
Temperature : 0 to 50°C (32 to 122°F)
Relative Humidity : 0 to 90% @ 30°C,
0 to 80% @ 40°C, 0 to 70% @ 50°C,
noncondensing
Regulatory2100Q : Meets EPA Method 180.1
2100Qis : Meets ISO 7027
Storage
Conditions
-40 to 60°C (-40 to 140°F),
instrument only
Light
Source
2100Q : Tungsten filament lamp
2100Qis: Light-emitting diode (LED) @ 860 nm
LanguagesEnglish, French, German, Italian, Spanish,Portuguese (BR), Portuguese (PT), Bulgarian,Chinese, Czech, Danish, Dutch, Finnish, Greek,
Hungarian, Japanese, Korean, Polish, Romanian,Russian, Slovenian, Swedish, Turkish
Range0 to 1000 NTU (FNU)InterfaceOptional USB
Accuracy± 2 % of reading plus stray
light from 0 to 1000 NTU
Instrument
Enclosure Rating
IP67 (closed lid, battery
compartment excluded)
Repeatability± 1% of reading, or 0.01 NTU (FNU),
whichever is greater
Protection
Class
Power Supply : Class II
Resolution0.01 NTU on lowest rangeCertificationCE certified
Stray Light<0.02 NTU (FNU)Sample Required15 mL (0.3 oz.)
Signal
Averaging
Selectable on/offSample
Cells
60 x 25 mm (2.36 x 1 in.)
borosilicate glass with screw cap
DetectorSilicon photovoltaicDimensions22.9 x 10.7 x 7.7 cm , (9.0 x4.2 x 3.0 in.)
Reading Modes
(user selectable)
Normal (Push to Read)
Signal Averaging
Rapidly Settling Turbidity
Weight527 g (1.16 lb) without batteries 618 g
(1.36 lb) with four AA alkaline batteries
Data Logger500 records
Warranty
1
Power
Requirement
110-230 Vac, 50/60 Hz
(with Power or USB+Power Module)
4 AA alkaline batteries Rechargeable NiMH (for use with USB+Power Module)

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Key Features
On-Screen Assisted Calibration and Verification
The 2100Q gives you confidence that your results are accurate, without having to read long manuals for calibration and verification instructions. All the core measurement information is on a single screen.

Rapidly Settling Turbidity™ (RST) Mode
At the request of our customers, Hach has developed an innovative solution to alleviate the uncertainty caused by changing turbidity readings in samples that quickly settle. The 2100Q’s RST reading mode uses an exclusive algorithm that reverse calculates and continuously updates a calculated value of turbidity to a point in time when the sample begins to settle out of solution based upon the accumulated trend of the measured values. This results in values that are more accurate and repeatable than those obtained using traditional smoothing techniques, such as averaging.

Customize Power and Connectivity with Flexible Modules

USB+Power Module 

(Prod. No. LZV813)


  • Line power: 110 - 230Vac, 50/60 Hz                      

  • Charges NiMH batteries

  • Transfers data to computer or printer

  • Enables firmware updates

Power Only Module 

(Prod. No. LZV804)


  • Line power: 110 - 230Vac, 50/60 Hz

Ordering Information

Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure

Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and on CD-ROM), quick start guide, silicone oil and oiling cloth.

  • 2100Q-01     2100Q Portable Turbidimeter (meets EPA method 180.1)

  • 2100QIS-01     2100Qis Portable Turbidimeter (meets ISO 7027)


Hach 2100Q and 2100Qis Portable Turbidimeters

Optional Accessories
Replacement Parts
LZV813
USB+Power Module2971205StablCal ampule calibration kit, 2100Q
(includes: universal power supply,
USB cables, instruction sheet)
296170110 NTU Verification Standard
LZV804Power Module (includes : universal power
supply, instruction sheet)
126936Silicone Oil, 15 mL
2960100Citizen PD-24 Printer Package2971507Insert, molded bottom,
2100Q carrying case
2971304Battery, NiMH AA, pk/4 4397500
Degassing Kit
4707600Sample Cell Oiling Cloth
4397510Sample Filtration and
Degassing Kit
24347061"glass sample cell (10ml )
w / cap (Turb) pkg/6
2971210StablCal 100 mL
calibration kit, 2100Q
2971500Carrying case for 2100Q
(includes insert)
2971200StablCal 500 mL
calibration kit, 2100Q
4653900Lamp assembly
2464105Gelex Secondary Standard Set1938004Battery set, 4x AA alkaline batteries

Hach 2100Q and 2100Qis Portable Turbidimeters

Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di : 

0 Komentar: