Kalibrasi Portable Turbidity Meter
Easiest calibration and verification with accurate results every time.
The Hach 2100Q and 2100Qis Portable Turbidimeters offer unsurpassed ease of use and accuracy in turbidity measurement. Only Hach offers this combination of advanced features including assisted calibration, simplified data transfer, and innovative measurement techniques that give you accurate results every time.
Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure
Easy On-Screen Assisted Calibration and Verification
The 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal™ calibration offer a simplified solution for low level measurements. | Convenient Data Logging
Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result. |
Simple Data Transfer
Customizable power and connectivity modules provide smooth data transfer and flexibility. Optional USB+Power Module allows data download to any computer via USB port, providing superior data integrity and availability.
| Optical System for Precision in the Field
The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, allowing you to achieve laboratory-grade performance on a wide range of samples, even under di@cult site conditions.
|
Accuracy for Rapidly Settling Samples
The innovative Rapidly Settling Turbidity™ mode provides accurate, repeatable measurements for di@cult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating. | Two Models forpecific USEPA Requirements
The 2100Q Turbidimeter is compliant with USEPA Method 180.1 design criteria. The 2100Qis Turbidimeter is compliant with ISO 7027 design criteria. |
Kalibrasi Portable Turbidity Meter
Hach 2100Q and 2100Qis Portable Turbidimeters |
Specification |
Measurement Method | Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) to the transmitted light scatter signal. | Operating Conditions | Temperature : 0 to 50°C (32 to 122°F) Relative Humidity : 0 to 90% @ 30°C, 0 to 80% @ 40°C, 0 to 70% @ 50°C, noncondensing |
Regulatory | 2100Q : Meets EPA Method 180.1 2100Qis : Meets ISO 7027 | Storage Conditions | -40 to 60°C (-40 to 140°F), instrument only |
Light Source | 2100Q : Tungsten filament lamp 2100Qis: Light-emitting diode (LED) @ 860 nm | Languages | English, French, German, Italian, Spanish,Portuguese (BR), Portuguese (PT), Bulgarian,Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian,Russian, Slovenian, Swedish, Turkish |
Range | 0 to 1000 NTU (FNU) | Interface | Optional USB |
Accuracy | ± 2 % of reading plus stray light from 0 to 1000 NTU | Instrument Enclosure Rating | IP67 (closed lid, battery compartment excluded) |
Repeatability | ± 1% of reading, or 0.01 NTU (FNU), whichever is greater | Protection Class | Power Supply : Class II |
Resolution | 0.01 NTU on lowest range | Certification | CE certified |
Stray Light | <0.02 NTU (FNU) | Sample Required | 15 mL (0.3 oz.) |
Signal Averaging | Selectable on/off | Sample Cells | 60 x 25 mm (2.36 x 1 in.) borosilicate glass with screw cap |
Detector | Silicon photovoltaic | Dimensions | 22.9 x 10.7 x 7.7 cm , (9.0 x4.2 x 3.0 in.) |
Reading Modes (user selectable) | Normal (Push to Read) Signal Averaging Rapidly Settling Turbidity | Weight | 527 g (1.16 lb) without batteries 618 g (1.36 lb) with four AA alkaline batteries |
Data Logger | 500 records | Warranty | 1 |
Power Requirement | 110-230 Vac, 50/60 Hz (with Power or USB+Power Module) 4 AA alkaline batteries Rechargeable NiMH (for use with USB+Power Module) |
Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure
Key Features
On-Screen Assisted Calibration and Verification
The 2100Q gives you confidence that your results are accurate, without having to read long manuals for calibration and verification instructions. All the core measurement information is on a single screen.
Rapidly Settling Turbidity™ (RST) Mode
At the request of our customers, Hach has developed an innovative solution to alleviate the uncertainty caused by changing turbidity readings in samples that quickly settle. The 2100Q’s RST reading mode uses an exclusive algorithm that reverse calculates and continuously updates a calculated value of turbidity to a point in time when the sample begins to settle out of solution based upon the accumulated trend of the measured values. This results in values that are more accurate and repeatable than those obtained using traditional smoothing techniques, such as averaging.
Customize Power and Connectivity with Flexible Modules
USB+Power Module (Prod. No. LZV813)
| Power Only Module (Prod. No. LZV804)
|
Ordering Information
Click Here : HACH 2100Q and 2100Qis Portable Turbidimeter Brochure
Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and on CD-ROM), quick start guide, silicone oil and oiling cloth.
Kalibrasi Portable Turbidity Meter
Optional Accessories | | Replacement Parts |
LZV813 | USB+Power Module | 2971205 | StablCal ampule calibration kit, 2100Q |
(includes: universal power supply, USB cables, instruction sheet) | 2961701 | 10 NTU Verification Standard |
LZV804 | Power Module (includes : universal power supply, instruction sheet) | 126936 | Silicone Oil, 15 mL |
2960100 | Citizen PD-24 Printer Package | 2971507 | Insert, molded bottom, 2100Q carrying case |
2971304 | Battery, NiMH AA, pk/4 4397500 Degassing Kit | 4707600 | Sample Cell Oiling Cloth |
4397510 | Sample Filtration and Degassing Kit | 2434706 | 1"glass sample cell (10ml ) w / cap (Turb) pkg/6 |
2971210 | StablCal 100 mL calibration kit, 2100Q | 2971500 | Carrying case for 2100Q (includes insert) |
2971200 | StablCal 500 mL calibration kit, 2100Q | 4653900 | Lamp assembly |
2464105 | Gelex Secondary Standard Set | 1938004 | Battery set, 4x AA alkaline batteries |
Kalibrasi Portable Turbidity Meter
Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :