We combine ease of use with reliability for your routine analysis and research applications. Our product offers the measurement range of 190-1100nm at bandwidth of 1.8nm/4m which provides better performance and increases lab productivity. Its affordable price and availability of optional accessories make it a versatile addition to your lab Wavelength range: 190nm-1100nm Optical System: Double beam optical system Czerny-Turner diffraction monochromator having 1200 lines/mm grating Bandwidth: 1.8nm/4nm Detector: Silicon Photodiode Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light (≤0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190 - 1100 nm Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements.

Scanning UV Visible Spectrophotometer

Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting. With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data. Automatic 4-position cell holder and optional 7-position or 16-position cell holder Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler USB data interface with online PC software ensures powerful function and data processing capabilities

Scanning UV Visible Spectrophotometer

MODEL / TYPEScanning UV Visible
Spectrophotometer BSSCU-101
Scanning UV Visible
Spectrophotometer BSSCU-102
Scanning UV Visible
Spectrophotometer BSSNU-101
Wavelength
Range
190-1100 nm190-1100 nm190-1100 nm
Wavelength
Accuracy
±0.5 nm±0.5 nm±0.5 nm
Wavelength
Repeatability
0.3 nm0.3 nm0.3 nm
Spectral
Bandwidth
4 nm2 nm4 nm
Photometric
Range
0-200 %T, -0.3 - 3.0 A, 0-9999 C0-200 %T, -0.3 - 3.0 A, 0-9999 C0-200 %T, -0.3 - 3.0 A, 0-9999 C
Photometric
Accuracy
±0.5 %T or ±0.004 A @ 1A±0.5 %T or ±0.004 A @ 1A±0.5 %T or ±0.004 A @ 1A
Stability0.0008 A/h @ 500 nm0.0008 A/h @ 500 nm0.0008 A/h @ 500 nm
Baseline
Flatness
±0.002 A±0.002 A±0.002 A
Scan SpeedHi, Med., Low, Max 3000 nm/minHi, Med., Low, Max 3000 nm/minHi, Med., Low, Max 3000 nm/min
Stray Light0.05 %T @ 220 nm, 360 nm0.05 %T @ 220 nm, 360 nm0.05 %T @ 220 nm, 360 nm
Light SourceTungsten and Deuterium LampTungsten and Deuterium LampTungsten and Deuterium Lamp
Optical SystemSingle Beam , Grating 1200 lines/mmSingle Beam , Grating 1200 lines/mmSingle Beam , Grating 1200 lines/mm
Gross Dimension
(W/D/H)
491 x 365 x 180 mm491 x 365 x 180 mm491x365x180 mm
Display5 inches LCD (320*240 dots)5 inches LCD (320*240 dots)5 inches LCD (320*240 dots)
Weight
(Net/Gross)
14 kg14 kg14 kg
Power
Supply
AC110V / 220V ;
50Hz / 60Hz
AC110V / 220V ;
50Hz / 60Hz
AC110V / 220V ;
50Hz / 60Hz
MODEL / TYPEScanning UV Visible
Spectrophotometer BSSNU-102
Scanning UV Visible
Spectrophotometer BSSNU-103
Scanning UV Visible
Spectrophotometer BSSNU-104
Wavelength
Range
190-1100 nm190-1100 nm190-1100 nm
Wavelength
Accuracy
±0.5 nm±0.3 nm±0.3 nm
Wavelength
Repeatability
0.3 nm0.2 nm0.2 nm
Spectral
Bandwidth
2 nm1.8 nm1 nm
Photometric
Range
0-200 %T, -0.3 - 3.0 A, 0-9999 C0-200 %T, -0.3 - 3.0 A, 0-9999 C0-200 %T, -0.3 - 3.0 A, 0-9999 C
Photometric
Accuracy
±0.5 %T or ±0.004 A @ 1A±0.3 %T or ±0.003 A @ 1A±0.3 %T or ±0.003 A @ 1A
Stability0.0008 A/h @ 500 nm±0.0008 A/h @ 500 nm±0.0008 A/h @ 500 nm
Baseline
Flatness
±0.002 A±0.0015 A±0.0015 A
Scan SpeedHi, Med., Low, Max 3000 nm/minHi, Med., Low, Max 3000 nm/minHi, Med., Low, Max 3000 nm/min
Stray Light0.05 %T @ 220 nm, 360 nm0.05 %T @ 220 nm, 360 nm0.05 %T @ 220 nm, 360 nm
Light SourceTungsten and Deuterium LampTungsten and Deuterium LampTungsten and Deuterium Lamp
Optical SystemSingle Beam , Grating 1200 lines/mmSingle Beam , Grating 1200 lines/mmSingle Beam , Grating 1200 lines/mm
SoftwarePC SoftwarePC SoftwarePC Software
Gross Dimension
(W/D/H)
491x365x180 mm579x428x198 mm579x428x198 mm
Display5 inches LCD (320*240 dots)5 inches LCD (320*240 dots)5 inches LCD (320*240 dots)
Weight
(Net/Gross)
14 kg20 kg20 kg
Power
Supply
AC110V / 220V ;
50Hz / 60Hz
AC110V / 220V ;
50Hz / 60Hz
AC110V / 220V ;
50Hz / 60Hz

Scanning UV Visible Spectrophotometer

MODEL / TYPEScanning UV Visible
Spectrophotometer BSSUB-101
Scanning UV Visible
Spectrophotometer BSSUB-101-PC
Wavelength
Range
190-1100 nm190-1100 nm
Wavelength
Accuracy
±0.3 nm±0.3 nm
Wavelength
Repeatability
0.2 nm0.2 nm
Spectral
Bandwidth
1.8 nm0.5/1/2/4/5 nm variable
Photometric
Range
0.200 %T, -0.3-3.0 A0.200 %T, -0.3-3.0 A
Photometric
Accuracy
±0.002A(0~0.5A), ±0.003A (0.5~1A),
±0.3%T (0~100%T)
±0.002A(0~0.5A), ±0.003A (0.5~1A),
±0.3%T (0~100%T)
Stability±0.002 A/h at 500 nm±0.002 A/h at 500 nm
Baseline
Flatness
±0.0015A±0.0015A
Scan SpeedHigh, Med., Low, Max 2000 nm/minHigh, Med., Low, Max 2000 nm/min
Stray Light0.05 %T at (220/360 nm)0.05 %T at (220/360 nm)
Light SourceTungsten Halogen Lamp
and Deuterium Lamp
Tungsten Halogen Lamp
and Deuterium Lamp
Optical
System
Split Beam Ratio Monitoring,
Blazed Holographic Grating
(1200 lines/mm)
Split Beam Ratio Monitoring,
Blazed Holographic Grating
(1200 lines/mm)
SoftwarePC Scanning SoftwarePC Scanning Software
Gross Dimension
(W/D/H)
545 x 468 x 245mm635 x 515 x 255mm
DisplayGraphic LCDGraphic LCD
Weight
(Net/Gross)
19kgs / 24kgs19kgs / 24kgs
Power
Supply
AC110V / 220V ;
50Hz / 60Hz
AC110V / 220V ;
50Hz / 60Hz

Features
  • Wavelength range: 190nm-1100nm
  • Optical System: Double beam optical system
  • Czerny-Turner diffraction monochromator having 1200 lines/mm grating
  • Bandwidth : 1.8nm/4nm
  • Detector : Silicon Photodiode
  • Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light (≤0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190 - 1100 nm
  • Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths
  • Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements.
  • Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting.
  • With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data.
  • USB data interface with online PC software ensures powerful function and data processing capabilities
  • Automatic 4-position cell holder and optional 7-position or 16-position cell holder
  • Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler
  • Click Here : BIOLAB - Scanning UV Visible Spectrophotometer Brochure
  • NB : PT.Mora Anugerah Berkat sudah terdaftar di E-Katalog LKPP

Applications

Ideal for life science, QA, pharmaceuticals, clinical, environmental and general quality control applications.

PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan general laboratorium seperti Scanning UV Visible Spectrophotometer , kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply / tawarkan seperti : Thermo Scientific, Shimadzu, Agilent, Hach, Biolabs dan lain - lain ; Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

Scanning UV Visible Spectrophotometer

Komentar