Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes.
The GENESYS 50 is a dual beam UV-Vis spectrophotometer in a single-cell configuration that meets all of the specifications for critical quality control applications and precise chemical measurements. The GENESYS 40 Dual Beam Vis Spectrophotometer is a visible spectral region version in this instrumental class. Both feature data resolution from 0.2 nm to 5 nm.
Thermo Scientific GENESYS 50 Vis/UV-Vis Spectrophotometers
| Catalog Number | GENESYS 30 Visible Spectrophotometer |
| 840-277000 | |
| Detector Type | Silicon Photodiode |
| Display | 5 in. diagonal, 32 bit color display, 800 x 480 pixels |
| Photometric Accuracy Instrument | ± 0.002A (0 - 0.3A) 0.5 % of ABS reading (0.301A - 2.5A) |
| Printer | Thermal printer accessory with 80mm width paper |
| Wavelength Accuracy | ± 2nm |
| Baseline Flatness | < 0.003A 325nm – 1000nm smoothed |
| Compartments |
|
| Connections |
|
| Description | GENESYS 30 Visible Spectrophotometer |
| Dimensions (L x W x H) | 35.5 cm x 38.5 cm x 19.5 cm |
| Drift | < 0.002A/Hr At 500nm after 2hr warmup. Typical < 0.004A/hr after 1hr warmup |
| Electrical Requirements | External AC to DC converter. Voltage and Hz selected automatically, 100 - 250 Volts, 50 - 60 Hz |
| Keypad | Tactile rubber 23 keys with numeric keypad |
| Lamp | 1000 Hrs typical service life |
| Languages | English, Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
| Noise | ≤ 0.001A at 0A ≤ 0.001A at 1A ≤ 0.002A at 2A RMS at 500 nm. 60 consecutive measurements |
| Optical Design | Single beam |
| Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
| Photometric Range | -3A to +3A |
| Photometric Repeatability | ± 0.002 A Measured at 1.0 A @546nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | < 0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
| Wavelength Data Interval | 1nm |
| Wavelength Range | 325 nm – 1100 nm |
| Wavelength Repeatability | < ±1nm |
| Wavelength Scan Speed | Automatic – up to 1200 nm/min |
| Weight (Metric) | 7.5 kg |
| Unit Size | Each |
Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
Click Here : Thermo Scientific Genesys Spectrophotometer Series Catalog
Click Here : Thermo Scientific Genesys 30 Visible Spectrophotometer Catalog
| Catalog Number | GENESYS 40 Visible Spectrophotometer |
| 840-297000 | |
| Optical Design | Dual beam |
| Spectral Bandwidth | 5 nm |
| Wavelength Range | 325 nm – 1100 nm |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7 - Inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
| Photometric Accuracy Instrument | ± 0.002A at 0.5A ; ± 0.004A at 1.0A ; ±0.008A at 2.0A |
| Printer | Snap-on printer available |
| Wavelength Accuracy | ± 0.5 nm |
| Baseline Flatness | ± 0.005A |
| Compartments |
|
| Connections |
|
| Description | GENESYS 40 Visible Spectrophotometer |
| Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
| Drift | (At 500 nm after 1 hour warmup) <0.0010A/Hr |
| Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
| Keypad | Touchscreen |
| Lamp | Tungsten-Halogen (>1000 hours) |
| Noise | (RMS at 500 nm 60 consecutive measurements) : ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
| Optical Design | Dual Beam |
| Photometric Display | -3A to +5A |
| Photometric Range | -3A to +3.5A |
| Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05%T at 340 nm and 400 nm |
| Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
| Wavelength Range | 325 nm – 1100 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Wavelength Scan Speed | Automatic – up to 1800 nm/min |
| Weight (Metric) | 7.5 kg |
| Unit Size | Each |
Thermo Scientific GENESYS 50 Vis/UV-Vis Spectrophotometers
| Catalog Number | GENESYS 50 UV-Vis Spectrophotometer |
| 840-298000 | |
| Optical Design | Dual Beam |
| Spectral Bandwidth | 2 nm |
| Wavelength Range | 190 nm – 1100 nm |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7 - inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
| Photometric Accuracy Instrument | ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
| Printer | Snap-on printer available |
| Wavelength Accuracy | ±0.5 nm |
| Baseline Flatness | ±0.002A |
| Compartments |
|
| Connections |
|
| Description | GENESYS 50 UV-Vis Spectrophotometer |
| Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
| Drift | (At 500 nm after 1 hour warmup) < 0.0005A/Hr |
| Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
| Keypad | Touchscreen |
| Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
| Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
| Optical Design | Dual beam |
| Photometric Display | -3A to +5A |
| Photometric Range | -2A to +3.5A |
| Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | < 1.0%T 198 nm (KCl) , < 0.05%T at 220 nm (NaI), < 0.03%T at 340 nm (NaNO2) |
| Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
| Wavelength Range | 190 nm - 1100 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Wavelength Scan Speed | Slow, medium and fast - up to 1600 nm/min |
| Weight (Metric) | 7.5 kg |
| Unit Size | Each |
Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
Click Here : Thermo Scientific Genesys Spectrophotometer Series Catalog
Click Here : Thermo Scientific Genesys 30 Visible Spectrophotometer Catalog
Click Here : Thermo Scientific Genesys Spectrophotometer Series Catalog
Click Here : Thermo Scientific Genesys 30 Visible Spectrophotometer Catalog
| Catalog Number | GENESYS 140 Visible Spectrophotometer |
| 840-308000 | |
| Optical Design | Double Beam |
| Spectral Bandwidth | 5 nm |
| Wavelength Range | 325 nm – 1100 nm |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7-inch color touchscreen, tiltable, high definition, 800 × 1280 pixels |
| Photometric Accuracy Instrument | ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
| Printer | Snap-on printer available |
| Wavelength Accuracy | ±0.5 nm |
| Baseline Flatness | ±0.005A |
| Compartments | Accommodates (optional):
|
| Connections |
|
| Description | GENESYS 140 Visible Spectrophotometer |
| Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
| Drift | (At 500 nm after 1 hour warmup) <0.0010A/Hr |
| Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
| Keypad | Touchscreen |
| Lamp | Tungsten-Halogen (>1000 hours) |
| Noise | (RMS at 500 nm 60 consecutive measurements) ≤ 0.00020A at 0A at 260 and 500 nm ≤ 0.00030A at 1A at 260 and 500 nm ≤ 0.00040A at 2A at 260 and 500 nm |
| Optical Design | Dual beam |
| Photometric Display | -3A to +5A |
| Photometric Range | –3A to +3.5A |
| Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05%T at 340 nm and 400 nm |
| Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
| Wavelength Range | 325 nm – 1100 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Wavelength Scan Speed | Automatic – up to 1800 nm/min |
| Weight (Metric) | 7.5 kg |
| Unit Size | Each |
Thermo Scientific GENESYS 50 Vis/UV-Vis Spectrophotometers
| Catalog Number | GENESYS 180 UV-Visible Spectrophotometer |
| 840-309000 | |
| Optical Design | Double Beam |
| Spectral Bandwidth | 2 nm |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7-inch color touchscreen, tiltable, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ± 0.002A at 0.5A ± 0.004A at 1.0A ± 0.008A at 2.0A |
| Printer | Snap-on printer available |
| Wavelength Accuracy | ±0.5 nm |
| Baseline Flatness | ±0.002A |
| Compartments |
|
| Connections |
|
| Description | GENESYS 180 UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
| Drift | (At 500 nm after 1 hour warmup) <0.0005A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz. |
| Keypad | Touchscreen |
| Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
| Noise | (RMS at 500 nm 60 consecutive measurements) ≤ 0.00020A at 0A at 260 and 500 nm ≤ 0.00030A at 1A at 260 and 500 nm ≤ 0.00040A at 2A at 260 and 500 nm |
| Optical Design | Double Beam |
| Photometric Display | -3A to +5A |
| Photometric Range | –2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
| Wavelength Range | 190 nm – 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast - up to 1600 nm/min |
| Weight (Metric) | 7.5 kg |
| Warranty | 1 years standard |
| Unit Size | Each |
PT. Mora Anugerah Berkat sudah berpengalaman menjual dan mensupply keseluruh indonesia produk Thermo Scientific GENESYS 50 Vis/UV-Vis Spectrophotometers , kami juga menyediakan brand / merek yang lain yang sudah di kenal di indonesia seperti Biolab, Labtron, Hach, Shimadzu, Agilent serta berbagai merk china, kami juga menyediakan jasa perbaikan (SERVICE), jasa perawatan (MAINTENANCE) dan kami juga support KALIBRASI untuk sebab itu jangan ragu menghubungi kami marketing / sales kami siap membantu menjawab segala kebutuhan yang anda caridan membantu Kalibrasi (Calibration) jangan ragu untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :
Thermo Scientific GENESYS 50 Vis/UV-Vis Spectrophotometers
- PT. Mora Anugerah Berkat (M.A.B)
- Click Here : Thermo Scientific Genesys 180 UV-VIS Spectrophotometer Brochure
- NB : PT. Mora Anugerah Berkat Telah Terdaftar di E-Catalog
- Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
- Phone : (+62) 021 7345.7064
- Mobile/HP : 0812.8140.0749 / 0812.8770.5470
- Chat : Whats App, Line, WeChat, Telegram
- Website : www.moraanugerah.id -
- www.moraanugerah.com
- Email : info@moraanugerah.com -
- marketing@moraanugerah.com -
- marketing_div@moraanugerah.com
genesis spectrophotometer
genesys uv-vis spectrophotometer
spektrofotometer uv/vis
thermo fisher scientific
thermo scientific genesis
thermo scientific spectrophotometer
thermo spectrophotometer uv-vis
- Dapatkan link
- X
- Aplikasi Lainnya
Komentar
Posting Komentar