Genesys Vis and UV-Vis Spectrophotometers
PT. Mora Anugerah Berkat (M.A.B) adalah perusahaan yang bergerak dalam bidang laboratorium khususnya material testing seperti alat spectrometry atau spectrophotometer, peralatan yang kami supply banyak di gunakan pada lembaga riset pemerintah, universitas / politeknik dan industrial (manufaktur) ; kami sudah berpengalaman dalam mensupply, instalasi dan training spectrophotometer diseluruh indonesia.
The GENESYS 180 UV-Vis Spectrophotometer provides double beam operation for laboratories requiring a reference cell position for applications such as kinetics. An 8-cell carousel comes standard for high-throughput applications. The spectrophotometer includes room-light resistance, allowing lid-open operation for improved speed and convenience. A full line of accessories, including automated cell changers and cell holders, sipper, and fiber optic probes for measurments outside of the sample compartment are designed to simplify sampling and accommodate high throughput measurements and temperature control.
Berikut ini tautan / link product dari UV and UV-Vis Spectrophotometer Series :
Perform high throughput quantitative UV-Vis measurements where a double beam is required as a reference cell position with the Thermo Scientific™ GENESYS™ 180 UV-Visible Spectrophotometer. Optimized for usability and performance, this platform features a high-resolution color touchscreen, optional Wi-Fi networking, and a rugged design built for repetitive, heavy use environments. Regarded worldwide for reliability, accuracy and reproducibility, GENESYS spectrophotometers meet today’s expectations for advanced technology in a compact, robust package.
Genesys Vis and UV-Vis Spectrophotometers
Berikut Thermo Scientific Genesys Spectrophotometer Series dengan specifikasi sebagai berikut :
Catalog Number | GENESYS 180 UV-Visible Spectrophotometer |
840-309000 |
Optical Design | Double Beam |
Spectral Bandwidth | 2 nm |
Detector Type | Dual Silicon Photodiodes |
Display | 7-inch color touchscreen, tiltable, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ± 0.002A at 0.5A ± 0.004A at 1.0A ± 0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ±0.5 nm |
Baseline Flatness | ±0.002A |
Compartments | - 8-position cell changer (standard) ; Also accommodates (optional):
- 4-position cell changer (long path cells)
- Peltier thermostatted cell holder (20-60 °C)
- Sipper accessory
- Fiber optic probe coupler
|
Connections | - Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
- Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
|
Description | GENESYS 180 UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0005A/Hr |
Electrical Requirements | External AC to DC Converter. Voltage and Frequency (Hz) selected automatically. 100 - 240 Volts, 50 - 60 Hz |
Keypad | Touchscreen |
Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤ 0.00020A at 0A at 260 and 500 nm ≤ 0.00030A at 1A at 260 and 500 nm ≤ 0.00040A at 2A at 260 and 500 nm |
Optical Design | Double Beam |
Photometric Display | -3A to +5A |
Photometric Range | –2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 2 nm |
Stray Light | < 1.0%T 198 nm (KCl) , < 0.05%T at 220 nm (NaI), < 0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range | 190 nm – 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast - up to 1600 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
====================
Catalog Number | GENESYS 50 UV-Vis Spectrophotometer |
840-298000 |
Optical Design | Dual Beam |
Spectral Bandwidth | 2 nm |
Wavelength Range | 190 nm – 1100 nm |
Detector Type | Dual Silicon Photodiodes |
Display | 7 - inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ±0.5 nm |
Baseline Flatness | ±0.002A |
Compartments | - Accessible from top, front or side Able to accommodate cells up to 100mm cells
- Available accessory for test tubes up to 25 mm diameter and 150 mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
- Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor,available Print via USB, Ethernet or Wi-Fi USB adaptor available
|
Description | GENESYS 50 UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0005A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad | Touchscreen |
Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Dual beam |
Photometric Display | -3A to +5A |
Photometric Range | –2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 2 nm |
Stray Light | < 1.0%T 198 nm (KCl) , < 0.05%T at 220 nm (NaI), < 0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range | 190 nm – 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast - up to 1600 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
====================
Catalog Number | GENESYS 40 Visible Spectrophotometer |
840-297000 |
Optical Design | Dual beam |
Spectral Bandwidth | 5 nm |
Wavelength Range | 325 nm – 1100 nm |
Detector Type | Dual Silicon Photodiodes |
Display | 7 - Inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ± 0.002A at 0.5A ; ± 0.004A at 1.0A ; ±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ± 0.5 nm |
Baseline Flatness | ± 0.005A |
Compartments | - Accessible from top, front or side Able to accommodate cells up to 100mm cells
- Available accessory for test tubes up to 25 mm diameter and 150 mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
- Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
|
Description | GENESYS 40 Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0010A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad | Touchscreen |
Lamp | Tungsten-Halogen (>1000 hours) |
Noise | (RMS at 500 nm 60 consecutive measurements) : ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Dual Beam |
Photometric Display | -3A to +5A |
Photometric Range | –3A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 5 nm |
Stray Light | <0.05%T at 340 nm and 400 nm |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range | 325 nm – 1100 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Automatic – up to 1800 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
====================
Catalog Number | GENESYS 30 Visible Spectrophotometer |
840-277000 |
Detector Type | Silicon Photodiode |
Display | 5 in. diagonal, 32 bit color display, 800 x 480 pixels |
Photometric Accuracy Instrument | ± 0.002A (0 - 0.3A) 0.5 % of ABS reading (0.301A - 2.5A) |
Printer | Thermal printer accessory with 80mm width paper |
Wavelength Accuracy | ± 2nm |
Baseline Flatness | < 0.003A 325nm – 1000nm smoothed |
Compartments | - Accessible from top, front or side
- Able to accommodate cells up to 100mm pathlength
- Available accessory for test-tubes up to 25mm diameter and 150mm height
- Removable, washable sample compartment liner with magnetic placement and hold-down
|
Connections | - USB-A on front face supports flash memory devices for method and data storage.
- USB-B on side supports connection to a Windows™ computer running optional remote control software.
|
Description | GENESYS 30 Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5 cm x 38.5 cm x 19.5 cm |
Drift | < 0.002A/Hr At 500nm after 2hr warmup. Typical < 0.004A/hr after 1hr warmup |
Electrical Requirements | External AC to DC converter. Voltage and Hz selected automatically, 100 - 250 Volts, 50 - 60 Hz |
Keypad | Tactile rubber 23 keys with numeric keypad |
Lamp | 1000 Hrs typical service life |
Languages | English, Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Noise | ≤ 0.001A at 0A ≤ 0.001A at 1A ≤ 0.002A at 2A RMS at 500 nm. 60 consecutive measurements |
Optical Design | Single beam |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Photometric Range | -3A to +3A |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A @546nm |
Spectral Bandwidth | 5 nm |
Stray Light | < 0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Wavelength Data Interval | 1nm |
Wavelength Range | 325 nm – 1100 nm |
Wavelength Repeatability | < ±1nm |
Wavelength Scan Speed | Automatic – up to 1200 nm/min |
Weight (Metric) | 7.5 kg |
Unit Size | Each |
Berikut ini tautan / link product dari UV and UV-Vis Spectrophotometer Series :
PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan laboratorium untuk seperti Genesys Vis and UV-Vis Spectrophotometers, kami juga menyediakan peralatan yang sudah teruji dan sesuai dengan ASTM,kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : Thermo Scientific (Thermo Fisher), Hach, Benchmark Scientific, Horiba, Biolab dan lain - lain.
Genesys Vis and UV-Vis Spectrophotometers
Kami juga menyediakan Jasa Perbaikan (SERVICE),Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda
PT. Mora Anugerah Berkat (M.A.B)
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
Phone : 021 7345.7064 / 7366.0160
Mobile: 0812.8140.0749 / 0812.8770.5470
Chat : Whats App, Line, WeChat, Telegram
Website : www.moraanugerah.id - www.moraanugerah.com
Email : info@moraanugerah.com - info@moraanugerah.id -marketing_div@moraanugerah.com
Komentar
Posting Komentar