Get high precision and functionality in a simple yet sophisticated visible spectrophotometer. The Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer performs both basic and complex analyses for educational or industrial use. Its intuitive design allows students and teachers to focus on scientific data and concepts rather than on learning how to use the instrument. In the lab, technicians of all levels working in routine QA/QC applications can easily obtain credible results to confirm quality or inform next steps. Results can be reported quickly as digital or printed data.

The GENESYS 30 visible spectrophotometer brings you intuitive design, a high definition color screen, fast and accurate measurements, and convenient data reporting. It is the ideal instrument for any user, whether a novice student or an experienced lab associate.

Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue

Product Features:
  • Entirely new industrial design for better usability
  • High definition 5-inch color screen with rubberized push-button keypad for easy navigation
  • Single cell measurement with removable, washable sample compartment liner
  • Standard cell holder for 10mm cuvettes and optional holders for other cell types including test-tubes
  • New onboard software UI; Thermo Scientific™ VISIONlite PC software is optional : 
    • Data any way you want it
    • USB data export in a text format that’s easy to read and process
  • Excellent snap-on thermal printer available
  • NB : PT. Mora Anugerah Berkat Telah Terdaftar di E-Catalog

Meets curriculum topics for:
  • Single wavelength
  • Scanning
  • Beer’s Law
  • Colorimetry/colorimetric analysis
  • Quantitative analysis

Lab associate benefits:
  • Higher data confidence with 6-point quant plus concentration mode
  • Multiple local language choices
Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue

Catalog Number
GENESYS 30 Visible Spectrophotometer
840-277000
Detector TypeSilicon Photodiode
Display5 in. diagonal, 32 bit color display, 800 x 480 pixels
Photometric
Accuracy
Instrument
± 0.002A (0 - 0.3A) 0.5 % of ABS reading (0.301A - 2.5A)
PrinterThermal printer accessory with 80mm width paper
Wavelength
Accuracy
± 2nm
Baseline
Flatness
< 0.003A 325nm – 1000nm smoothed
Compartments
  • Accessible from top, front or side
  • Able to accommodate cells up to 100mm pathlength
  • Available accessory for test-tubes up to 25mm diameter and 150mm height
  • Removable, washable sample compartment liner with magnetic placement and hold-down
Connections
  • USB-A on front face supports flash memory devices for method and data storage.
  • USB-B on side supports connection to a Windows™ computer running optional remote control software.
DescriptionGENESYS 30 Visible Spectrophotometer
Dimensions
(L x W x H)
35.5 cm x 38.5 cm x 19.5 cm
Drift< 0.002A/Hr At 500nm after 2hr warmup.
Typical < 0.004A/hr after 1hr warmup
Electrical
Requirements
External AC to DC converter.
Voltage and Hz selected automatically, 100 - 250 Volts, 50 - 60 Hz
KeypadTactile rubber 23 keys with numeric keypad
Lamp1000 Hrs typical service life
LanguagesEnglish, Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic
Noise≤ 0.001A at 0A
≤ 0.001A at 1A
≤ 0.002A at 2A
RMS at 500 nm. 60 consecutive measurements
Optical DesignSingle beam
Photometric
Display
-3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C
Photometric
Range
-3A to +3A
Photometric
Repeatability
± 0.002 A Measured at 1.0 A @546nm
Spectral
Bandwidth
5 nm
Stray Light< 0.1%T at 340 nm and 400 nm Measured using glass
cutoff filters or NaNO2 at 340 nm
Wavelength
Data Interval
1nm
Wavelength
Range
325 nm – 1100 nm
Wavelength
Repeatability
< ±1nm
Wavelength
Scan Speed
Automatic – up to 1200 nm/min
Weight (Metric)7.5 kg
Unit SizeEach

Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
Click Here : Thermo Scientific Genesys Spectrophotometer Series Catalog
Click Here : Thermo Scientific Genesys 30 Visible Spectrophotometer Catalog

Catalog Number
GENESYS 40 Visible Spectrophotometer
840-297000
Optical
Design
Dual beam
Spectral
Bandwidth
5 nm
Wavelength
Range
325 nm – 1100 nm
Detector
Type
Dual Silicon Photodiodes
Display7 - Inch color touchscreen, fixed, high definition,
800 × 1280 pixels
Photometric
Accuracy
Instrument
± 0.002A at 0.5A ; ± 0.004A at 1.0A ; ±0.008A at 2.0A
PrinterSnap-on printer available
Wavelength
Accuracy
± 0.5 nm
Baseline
Flatness
± 0.005A
Compartments
  • Accessible from top, front or side Able to accommodate cells up to 100mm cells
  • Available accessory for test tubes up to 25 mm diameter and 150 mm height
  • Removable, washable sample compartment liner with magnetic placement and hold-down
Connections
  • Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
  • Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
DescriptionGENESYS 40 Visible Spectrophotometer
Dimensions
(L x W x H)
35.5 x 38.5 x 19.5 cm
Drift(At 500 nm after 1 hour warmup) <0.0010A/Hr
Electrical
Requirements
External AC to DC converter. Voltage and Frequency (Hz)
selected automatically, 100 – 240 Volts, 50 – 60 Hz.
KeypadTouchscreen
LampTungsten-Halogen (>1000 hours)
Noise(RMS at 500 nm 60 consecutive measurements) :
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Optical DesignDual Beam
Photometric
Display
-3A to +5A
Photometric
Range
-3A to +3.5A
Photometric
Repeatability
±0.001A at 1A measured at 1.0A at 546 nm
Spectral
Bandwidth
5 nm
Stray Light<0.05%T at 340 nm and 400 nm
Wavelength
Data Interval
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength
Range
325 nm – 1100 nm
Wavelength
Repeatability
< ±0.2 nm
Wavelength
Scan Speed
Automatic – up to 1800 nm/min
Weight (Metric)7.5 kg
Unit SizeEach

Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue

Catalog Number
GENESYS 50 UV-Vis Spectrophotometer
840-298000
Optical
Design
Dual Beam
Spectral
Bandwidth
2 nm
Wavelength
Range
190 nm – 1100 nm
Detector
Type
Dual Silicon Photodiodes
Display7 - inch color touchscreen, fixed, high definition,
800 × 1280 pixels
Photometric
Accuracy
Instrument
±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A
PrinterSnap-on printer available
Wavelength
Accuracy
±0.5 nm
Baseline
Flatness
±0.002A
Compartments
  • Accessible from top, front or side Able to accommodate cells up to 100mm cells
  • Available accessory for test tubes up to 25 mm diameter and 150 mm height
  • Removable, washable sample compartment liner with magnetic placement and hold-down
Connections
  • Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
  • Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor,available Print via USB, Ethernet or Wi-Fi USB adaptor available
DescriptionGENESYS 50 UV-Vis Spectrophotometer
Dimensions
(L x W x H)
35.5 x 38.5 x 19.5 cm
Drift(At 500 nm after 1 hour warmup) < 0.0005A/Hr
Electrical
Requirements
External AC to DC converter. Voltage and Frequency (Hz)
selected automatically, 100 – 240 Volts, 50 – 60 Hz.
KeypadTouchscreen
LampXenon Flash Lamp (>5 years typical, 3 years guaranteed)
Noise(RMS at 500 nm 60 consecutive measurements)
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Optical
Design
Dual beam
Photometric
Display
-3A to +5A
Photometric
Range
-2A to +3.5A
Photometric
Repeatability
±0.001A at 1A measured at 1.0A at 546 nm
Spectral
Bandwidth
2 nm
Stray Light< 1.0%T 198 nm (KCl) ,
< 0.05%T at 220 nm (NaI),
< 0.03%T at 340 nm (NaNO2)
Wavelength
Data Interval
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength
Range
190 nm - 1100 nm
Wavelength
Repeatability
< ±0.2 nm
Wavelength
Scan Speed
Slow, medium and fast - up to 1600 nm/min
Weight (Metric)7.5 kg
Unit SizeEach

Berikut ini tautan / link product dari Thermo Scientific Spectrophotometer Series:
Click Here : Thermo Scientific Genesys Spectrophotometer Series Catalog
Click Here : Thermo Scientific Genesys 30 Visible Spectrophotometer Catalog


Catalog Number
GENESYS 140 Visible Spectrophotometer
840-308000
Optical DesignDouble Beam
Spectral
Bandwidth
5 nm
Wavelength
Range
325 nm – 1100 nm
Detector TypeDual Silicon Photodiodes
Display7-inch color touchscreen, tiltable,
high definition, 800 × 1280 pixels
Photometric
Accuracy
Instrument
±0.002A at 0.5A
±0.004A at 1.0A
±0.008A at 2.0A
PrinterSnap-on printer available
Wavelength
Accuracy
±0.5 nm
Baseline
Flatness
±0.005A
CompartmentsAccommodates (optional):
  • 8-position cell changer
  • 4-position cell changer (long path cells)
  • Peltier thermostatted cell holder (20-60 °C) Sipper accessory
  • Fiber optic probe coupler
Connections
  • Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
  • Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
DescriptionGENESYS 140 Visible Spectrophotometer
Dimensions
(L x W x H)
35.5 x 38.5 x 19.5 cm
Drift(At 500 nm after 1 hour warmup) <0.0010A/Hr
Electrical
Requirements
External AC to DC converter. Voltage and Frequency (Hz)
selected automatically, 100 – 240 Volts, 50 – 60 Hz.
KeypadTouchscreen
LampTungsten-Halogen (>1000 hours)
Noise(RMS at 500 nm 60 consecutive measurements)
≤ 0.00020A at 0A at 260 and 500 nm
≤ 0.00030A at 1A at 260 and 500 nm
≤ 0.00040A at 2A at 260 and 500 nm
Optical DesignDual beam
Photometric
Display
-3A to +5A
Photometric
Range
–3A to +3.5A
Photometric Repeatability±0.001A at 1A measured at 1.0A at 546 nm
Spectral
Bandwidth
5 nm
Stray Light<0.05%T at 340 nm and 400 nm
Wavelength Data Interval0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength
Range
325 nm – 1100 nm
Wavelength Repeatability< ±0.2 nm
Wavelength Scan SpeedAutomatic – up to 1800 nm/min
Weight (Metric)7.5 kg
Unit SizeEach


Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue

Catalog Number
GENESYS 180 UV-Visible Spectrophotometer
840-309000
Optical DesignDouble Beam
Spectral Bandwidth2 nm
Detector TypeDual Silicon Photodiodes
Display7-inch color touchscreen, tiltable,
high definition, 800 × 1280 pixels
Photometric
Accuracy 
Instrument
± 0.002A at 0.5A
± 0.004A at 1.0A
± 0.008A at 2.0A
PrinterSnap-on printer available
Wavelength Accuracy±0.5 nm
Baseline Flatness±0.002A
Compartments
  • 8-position cell changer (standard) ; Also accommodates (optional):
  • 4-position cell changer (long path cells)
  • Peltier thermostatted cell holder (20-60 °C)
  • Sipper accessory
  • Fiber optic probe coupler
Connections
  • Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
  • Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
DescriptionGENESYS 180 UV-Vis Spectrophotometer
Dimensions
(L x W x H)
35.5 x 38.5 x 19.5 cm
Drift(At 500 nm after 1 hour warmup)
<0.0005A/Hr
Electrical
Requirements
External AC to DC converter.
Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz.
KeypadTouchscreen
LampXenon Flash Lamp
(>5 years typical, 3 years guaranteed)
Noise(RMS at 500 nm 60 consecutive measurements)
≤ 0.00020A at 0A at 260 and 500 nm
≤ 0.00030A at 1A at 260 and 500 nm
≤ 0.00040A at 2A at 260 and 500 nm
Optical DesignDouble Beam
Photometric Display-3A to +5A
Photometric Range–2A to +3.5A
Photometric
Repeatability
±0.001A at 1A measured at 1.0A at 546 nm
Spectral Bandwidth2 nm
Stray Light< 1.0%T 198 nm (KCl) ,
<0.05%T at 220 nm (NaI),
<0.03%T at 340 nm (NaNO2)
Wavelength
Data Interval
0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength
Range
190 nm – 1100 nm
Wavelength
Repeatability
< ±0.2 nm
Wavelength
Scan Speed
Slow, medium and fast - up to 1600 nm/min
Weight (Metric)7.5 kg
Warranty1 years standard 
Unit SizeEach

PT. Mora Anugerah Berkat sudah berpengalaman menjual dan mensupply keseluruh indonesia produk Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue , kami juga menyediakan brand / merek yang lain yang sudah di kenal di indonesia seperti Biolab, Labtron, Hach, Shimadzu, Agilent serta berbagai merk china, kami juga menyediakan jasa perbaikan (SERVICE), jasa perawatan (MAINTENANCE) dan kami juga support KALIBRASI untuk sebab itu jangan ragu menghubungi kami marketing / sales kami siap membantu menjawab segala kebutuhan yang anda caridan membantu Kalibrasi (Calibration) jangan ragu untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :

Thermo Scientific Evolution UV-Visible Spectrophotometer Catalogue
  • PT. Mora Anugerah Berkat (M.A.B)
  • Click Here : Thermo Scientific Genesys 180 UV-VIS Spectrophotometer Brochure
  • NB : PT. Mora Anugerah Berkat Telah Terdaftar di E-Catalog
  • Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
  • Phone : (+62) 021 7345.7064
  • Mobile/HP : 0812.8140.0749 / 0812.8770.5470
  • Chat : Whats App, Line, WeChat, Telegram
  • Website : www.moraanugerah.id -
  •                   www.moraanugerah.com
  • Email : info@moraanugerah.com -
  •              marketing@moraanugerah.com -
  •              marketing_div@moraanugerah.com

Komentar